TROUBLESHOOTING GUIDE

What do I need to check if drinks are not dispensing?
  1. Is there an empty box online?
  2. Are the box connectors fully tightened?
  3. Is the CO2 gas cylinder full?
  4. Is the CO2 gas turned on and showing pressure?
  5. Is the water turned on?
  6. Is the electricity switched on?
  7. Has the fuse blown?
What do I need to check if the drinks are weak?
  1. Is there an empty box online?
  2. Are the box connectors fully tightened?
  3. Is the CO2 gas turned on and showing pressure?
  4. Has the box been recently changed? If so, pull approximately 2 pints through.
What do I need to check if drinks are flat?
  1. Is the CO2 gas cylindar full?
  2. If the CO2 gas has been recently changed, pour approximately 8 pints of soda /carb water through the dispenser.
  3. Clean the dispenser nozzle
  4. Is the lager flat? If yes, renovate your glasses, to remove any build up of detergent on them.
  5. Is the cooler turned on and has an ice bank?
What do I need to check if no soda/carb water is dispensing?
  1. Is the electricity switched on?
  2. Is the water turned on?
  3. Reset the carbonator by turning off for 2 seconds and turning back on. Press and hold the soda button/lever for 15 seconds.